Enclosure Cooling

  • NOW AVAILABLE IN 48 VDC

  • Quality is our Standard

  • Leading the Industry

    The first and ONLY manufacturer to have UL listing on entire line of hazardous duty air Conditioners.
  • On Site Warranty Service

    Ice Qube, Inc offers an elevated standard level of commitment to our cooling systems.
  • Products available ONLY at Ice Qube

  • INDUSTRIES

    Your complete list for electronic enclosure cooling products can be found at Ice Qube
  • Digital Controller

    A Digital Controller comes in EVERY STANDARD unit. Ethernet Controller is available as an option.


Alarm Output


Wire Output lead provides a dry contact signal when an alarm condition occurs. Contact may be Normally Open, Normally Closed, or both Normally Open and Closed. Part Number for ordering: X03 - Dry Contacts - Normally Open/Closed

Condensate Evaporator


Recommended for extremely humid environments where condensate dripping onto the floor is prohibited or undesired.

Part # CEV3 - 600 Watt Condensate Evaporator 120V
Part # CEV4 - 600 Watt Condensate Evaporator 230V

condensate evaporator for air conditioners

Features: 

  • Stainless Steel Inner Pan
  • Stainless Steel 600 Watt Heating Element
  • Stainless Steel Float Switch To Prolong Life of Heating Element
  • Operational Indicator Light
  • Manual Reset High Limit Safety Switch
  • 2" Fan To Remove Steam and Prevent Condensation on Enclosure and Air Conditioners
  • Drain Tube, Template, and Mounting Hardware Included
  • 8' Power Cord
  • Overflow Drain Nipple

Corrosive Packages


Ice Qube corrosive environment coatings for enclosure air conditioners provide protection to components, such as coils and piping, against acids, solvents, salt, and other corrosive environments that may be present on the plant floor. The coating will withstand normal operating temperatures of -40deg F to 250deg F.

Ice Qube's part# CP1 option includes a baked polyester-enamel coating on the condenser coil and corrosive inhibitors applied to internal piping. Ice Qube's part# CP2 option includes the same coatings as the CP1 option plus the same coatings on the evaporator section of the air conditioner. All coating meets or exceeds ASTM specifications for aluminum, copper, and prephosphatized galvanized steel. Ask your Ice Qube representative for the ASTM specifications and listing of substances for which these coatings provide chemical or solvent resistance.

Filters


Standard Filter
Upgrade Option

All Ice Qube Air Conditioners and most fan systems use PermaCool™ electrostatic filter media to keep dust and other industrial residues from clogging the condenser cooling air passages.

The filter material is a rigid/durable 1/4" corrugated polypropylene media with 10 micron filtration which retains a low resistance to airflow. The filter will withstand harsh factory environments and will not degrade over time. Simple washing or vacuuming is all that is necessary to maintain the filter media over an indefinite period of time. PermaCool's dense 3 layer, 1/4" waffle weave configuration enhances its filtration abilities and creates a rigid electrostatic air filter. Unlike other media which may compress and restrict air flow, PermaCool retains its low resistance design.

enclosure a/c unit pull filter

For an additional cost, you may upgrade to a 4 micron electrostatic air filter for fine filtering.

This electrostatic media air filter contains 3 layers of media contained within a 1/4" stainless or galvanized steel frame. Layer one contains waffle corrugated black with blue polypropylene. Layer three contains black 12 mil huckaback woven polypropylene. Vinyl pull tab is installed in the center of one side for easy access.

Made of polypropylene, this filter has excellent strength and is very resistant to abrasion. It is light in weight and has smooth fibers that are easy to clean. Excellent resistance to most acids and alkalis. good resistance to bleaches and solvents. Not attacked by mildew. Also good resistance indirect sunlight and abrasion. Operating temperature 180 deg; Melting 325-350 deg F. UL Class 2.

Heaters


Electrical output used when a heater is required to maintain satisfactory temperature and humidity conditions. Output is driven by Ice Qube's Controller.
PTC FAN HEATERS
HVL FAN HEATERS
Available from
400 - 650 Watts
Available from
100 - 400 Watts

Low Ambient


Recommended for models used in an atmosphere where the ambient temperature may fall significantly below the enclosure temperature.
Part # for ordering with A/C Unit - LA

Metal Blower Wheels


Metal Blower Wheels are available as an option for most Enclosure Air Conditioners. Please call Ice Qube for more information.


metal blower wheels

NEMA 4/4X


When ordered with the NEMA 4 package, the air conditioner will maintain an enclosures NEMA 4 rating for indoor or outdoor use in a wet environment including rain, splashing, and hose directed water. The NEMA 4X package adds corrosion protection with a 304 stainless steel cabinet. It is recommended to include the coil protection option for NEMA 4X applications.

Remote Controller

May be located inside the enclosure for additional security or located on accessible enclosure surface for more convienent display control.
Part#
XC - Remote Controller

remoteSPEC SHEET

Thermal Management Center



All the features of the standard digital controller plus a lcd display, expanded temperature and alarm ranges, ethernet communications link
***The cutout template on Ethernet equipped units is different from the standard controller cutout template, please contact Ice Qube with any questions.
.

Washdown Hoods

Ambient Condenser Air Inlet and Exhaust Hoods for protection against directed water, splashing liquids, and severe outdoor applications.

Available in Stainless Steel and Painted Steel

washdown rainhoods for enclosure air conditioner

 


What is closed-loop cooling?

 

closed-loop cooling

Find Out.

Size your needs.

 

air conditioning sizing

Click Here